An RV water heater that is not working is usually out of propane, short on 12-volt or 120-volt power, shut down by a tripped safety reset, or cut off by a bypass valve left in its winterizing position. Run propane and electric separately, because the one that fails tells you where to look.
Which cause fits your symptom?
Many RV tank heaters have both a propane burner and a 120-volt electric element, while others are propane only. With the RV parked, try one energy source at a time and match what you see to the table.
| Symptom | Most likely cause | Check first |
|---|---|---|
| No heat on propane, electric works | Empty tank, closed valve, ignition lockout, tripped energy cut off (ECO) reset or low 12-volt power | Light a stove burner, then cycle the heater switch |
| No heat on electric, propane works | Tripped breaker, switch off, tripped ECO reset or burned-out element | Breaker panel, then the electric switch |
| No hot water on either, heater seems to run | Bypass valve open or leaking, so hot water never reaches the faucets | Bypass valves behind the heater |
| No heat on either, worked yesterday | Tripped ECO reset (some heaters have separate gas and electric resets), or two separate faults such as no propane and no shore power (campground electricity) | Each energy source, then the ECO reset if you can reach it without removing a cover |
| Hot water from the cold side of a single-lever faucet | Faulty faucet mixing valve or swapped hot and cold lines | Try a different faucet, then book a service center if you suspect swapped lines |
| Yellow or weak flame, or soot at the vent | Blocked burner tube or incomplete combustion, a fire and carbon monoxide hazard | Shut it down and call a technician |
Why is there no hot water on propane?
When a working heater suddenly stops on gas, check the propane first. An open valve on a nearly empty tank looks the same as a broken heater, so confirm the fuel before you suspect any parts.
The next suspect is 12-volt power. The burner’s control board and gas valve run on the RV’s battery system, so a drained battery, blown fuse or tripped breaker can stop the burner even with a full tank. An Atwood DSI gas valve, for example, needs at least 10.5 volts to open.
Many units use direct spark ignition (DSI), which lights the burner with an electronic spark rather than a standing pilot. If the burner does not catch after three tries, the board locks out until you reset it.
Air in the gas line can do this, especially after a first start-up, because purging it may take several ignition cycles.
Why is there no hot water on electric?
The electric element only runs when 120-volt power reaches it, so start with the basics. The element needs its own switch turned on, power at the RV, and an untripped breaker. On a typical 15-amp circuit, a 1,400-watt element pulls close to 12 amps by itself.
If power is good, the ECO switch may have tripped. This safety device cuts power to the heater when the tank gets too hot. If neither of those is the problem, the element itself may be burned out, which is what running it in an empty tank does.
A heater that works on propane but never on electric points to the element side, and that narrows the repair. It also means you still have hot water while you wait for a service appointment.
Why is there no hot water on either one?
When both energy sources seem dead, look at the water path before the heater. Bypass valves let water skip the tank during winterizing, and if one stays open, the tank can be hot while your faucets run cold.
The valve can also look closed without sealing, which gives you weak or lukewarm hot water. Some owners report other culprits, such as a broken or backward check valve (a one-way valve), or an outside shower left with both valves open.
Think of this first in spring. If you just followed our de-winterizing guide, or someone else opened up the rig, go to the bypass first.
What can you safely check yourself?
These checks need no tools, and none of them should involve opening a gas or electrical part. Work through them in order, because the later ones depend on the earlier ones.
- Set the bypass to normal. On a typical three-valve setup, the bypass handle sits across its line when closed, and the inlet and outlet handles sit in line with theirs when open. A single tee valve, which combines the cold water and bypass valves in one part, closes the bypass with its handle in line with the cold water line. Setups differ, so confirm yours in the RV manual. Our winterizing guide explains why the valve gets moved.
- Confirm the tank is full. With the pump or city water (a campground water hookup) on, open each hot faucet one at a time until water runs without spitting air. Do this before turning any heater switch on. Hydrogen risk: After two weeks or more unused, a heater can hold extremely flammable hydrogen gas, even if the tank was drained. Start at the kitchen hot faucet and let it run for several minutes (5 to 10 on a Suburban), with no smoking or open flame nearby. Do this before lighting the burner or using any electrical appliance connected to the hot water system.
- Check every switch. Many heaters have separate switches for gas and electric, and on a Suburban DE the electric switch sits behind the water heater door. Make sure the one you are testing is on.
- Check the propane. Confirm the tank has fuel and its service valve is open. If a stove burner lights and holds a steady blue flame, gas is reaching the RV, though a weak regulator can still starve the heater under load.
- Check 12-volt power. Look for a low battery, a blown fuse in the RV’s fuse panel or a tripped 12-volt breaker. Replace a fuse only with one of the same amperage. Fix what you find, then try again.
- Clear the lockout. Use the reset for your brand in the table below. If it keeps locking out, stop and book a technician.
- Check the ECO reset. Turn off the heater and let the water cool before pressing anything, and take care at hot faucets, because a trip can mean scalding water. Use the table below for your brand. On some Suburban SW models, the button sits behind a rubber plug called a grommet: Push in on the grommet and leave it in place. If reaching a button means removing any cover, stop and book a certified RV technician, because those covers can hide 120-volt wiring.
- Check the 120-volt breaker. Find the water heater breaker in the RV’s panel and flip it fully off, then on. If it trips again, leave it off. Our RV surge protector guide covers protecting the rig at the campground power pedestal.
| Brand and models | Clear a gas lockout | Clear an overheat trip |
|---|---|---|
| Suburban SW series with DSI | Switch off, wait 5 seconds, switch on | Let water cool, then push the reset button, pressing through the rubber grommet if your model has one. If you would have to remove a cover, book a technician |
| Dometic WH-6GA, WH-6GEA, WH-9GEA | Fix the cause, then switch off and back on | Let water cool, switch off, wait 30 seconds, switch on |
| Older Atwood DSI models | Switch off, then back on | Let water cool, switch off at least 30 seconds, switch on. If it stays locked out, or an electric-side ECO button sits behind a 120-volt junction box cover, book a technician |
Suburban’s reset trips above 180°F, but its manuals disagree on the cool-down target. Some say the water must be below 110°F before you push reset, others say 100°F, and its current owner guide gives no figure. Wait for the lower number.
A trip is a symptom, not a repair. Find and fix the cause of the overheating before you reset, and hand repeated trips to a technician. Older Atwood pilot models use a one-shot ECO in the gas control, which cannot be reset, so the control must be replaced.
What happens if the electric switch is on with an empty tank?
It can ruin the element quickly. On Suburban heaters, even brief dry operation can burn out the element, and an Atwood element lasts only a limited time. Running the burner on an empty tank is a problem too, because on a Suburban it can melt the insulation jacket and trip the ECO.
Turn the gas and electric switches off before you drain, and leave them off until the tank is full.
The risk comes up around winter storage, when the tank has been drained and someone plugs in with the switch still on. If propane still heats but electric never does afterward, suspect the element.
If you catch it while it is happening, turn the element off and do not refill right away. Older Atwood guidance is to let the tank cool for 2 to 3 hours first, because adding water too soon could collapse the tank. Replacing a burned-out element is a job for a technician.
What should you leave to a certified RV technician?
Stop at the checks above if the fix means opening a gas line, a burner assembly, an electrical box or any cover over 120-volt wiring. Manufacturers limit installation and service to qualified people for good reason.
Propane risk: A gas leak can cause a fire or explosion, and any smell of gas should be treated as life threatening.
If you smell gas, get everyone out, put out any flames, and shut the gas off at the tank. Leave switches, phones and radios alone inside the RV, and do not start the engine or generator. From outside, call your gas supplier or a qualified technician, or the fire department if you cannot reach one. Do not turn the gas back on until the leak is repaired.
120-volt risk: This power can cause a fatal shock or a fire. Do not open the element, thermostat or wiring yourself, or remove any cover over them. That work belongs to a certified RV technician.
Call a technician for any of these:
- A gas smell, or a heater that keeps locking out
- A yellow or soft flame, or soot at the vent
- Regulator, gas pressure, gas valve or control board work
- Insects in the burner tube, where spiders and mud wasps can build nests
- Element, thermostat or 120-volt wiring work, or anything else behind a 120-volt cover
- A breaker that trips again after you reset it
- Any heater that has been under water
Skip aftermarket heating elements, which can lack critical safety controls. The RV Technical Institute (RVTI) has a Find a Certified Technician map for the US and Canada. For the basics worth carrying on every trip, see our beginner accessories guide.
What about tankless RV water heaters?
Tankless units have no storage tank, but the same first checks apply: Propane, 12-volt power and water supply. Their water side still has to be filled: Before starting an AquaGo, close any open bypass and open the faucets until water flows, which bleeds the air.
Tankless units also need enough flow to start. The Truma AquaGo fires when flow passes about 0.4 gallons per minute, so a barely open faucet may stay cold.
An AquaGo reports faults by flash code at the unit or on a CP plus display, its digital control panel. These common codes have owner-level fixes.
| AquaGo code | Meaning | What to do |
|---|---|---|
| E 1 | No flame after repeated attempts | Check propane level and the service valve |
| W 27 | Circulation pump running dry | Open each hot faucet until air clears, then retry |
| W 29 | Too much hot water demand | Run fewer hot faucets at once |
| W 30 | Freeze risk inside the unit | Warm it, move it or drain it |
| W 31 | Decalcification finished, not a fault | Return to Eco or Comfort mode |
Code 28 means gas pressure is too low. Switch the unit off, wait 5 seconds and switch it on. If the code stays, call an authorized Truma service center. On a Suburban IW60, clear a lockout by turning the faucet off and on, or by cycling the on/off switch.
Procedures vary by model year, so your own manual comes first.
Sources
Researched from manufacturer manuals, support pages, RV industry references and an electric utility, all opened November 2026.
Suburban: Tank Water Heaters Operation and Maintenance Guide · Tankless Water Heaters Operation and Maintenance Guide · Suburban FAQs
Forest River: Suburban SW10D series operation manual · Suburban SW4D and SW6D series operation manual · Truma AquaGo error codes
ManualsLib: Suburban SW6D manual, thermostat and manual reset · Suburban SW6D manual, safety warnings · Suburban SW6P manual, reset · Suburban SW6P manual, scald warning · Atwood 4-E manual, electronic ignition lockout and reset
Dometic: L.P. Gas Water Heater Installation and Operation Manual · Dometic WH-6GEA 6 Gallon Water Heater
InspectAPedia: Atwood Water Heaters service manual · How to Reset a Circuit Breaker
Truma: Tech Tip: Truma AquaGo Error Codes · Truma AquaGo comfort
Tiffin Motorhomes: Truma AquaGo Comfort Operating Instructions
Camping World: RV Hot Water Heater Not Working?
RV Travel: Setting your RV water heater bypass valves · Water heater works but only cold water comes from faucets · RV’s water heater doesn’t get water hot on LP but does on 120 volts · My Suburban water heater doesn’t work on 120-volt power
RV Technical Institute: Find a Certified Technician
RVIA: RVTI’s New Find a Certified Technician Map Launches
Southern California Edison: How to Reset Breakers